Calculator Suite

Everything recomputes as you type. No submit buttons, no page reloads.

Using the same copper weight or units every time? Set your calculator defaults.

Trace Width

IPC-2221 or IPC-2152 — solve for required width or a trace's current capacity

Show your work
Solve for
Standard
Layer
Required width
30.8 mil
Required width
0.781 mm
Cross-section
42.4 mil²
Resistance
32.1 mΩ
Voltage drop
64.1 mV
Dissipation
128 mW
Formula
FR-4externalinternalWt
A=(Ik·ΔTb)1/c
W=At×1.378

Internal layers: k = 0.024, b = 0.44, c = 0.725

External layers: k = 0.048, b = 0.44, c = 0.725

  • I = current (A)
  • ΔT = allowed temperature rise (°C)
  • A = cross-section (mil²)
  • W = trace width (mil)
  • t = copper weight (oz); 1 oz of copper is 1.378 mil thick
  • k, b and c are curve-fit constants from IPC-2221's charts.

IPC-2221 is a conservative DC estimate for a bare trace in still air. Internal layers derate to roughly half the external current for the same geometry. Add margin for long runs, adjacent heat sources, and pulsed loads.